Water supply pipe size for 80 fixture units over a 250 ft run

80 supply fixture units over 250 ft
1¼″
80 WSFU is about 31 GPM at once — not 80 GPM
80 supply fixture units over 250 ft31 GPMSimultaneous dema…80 WSFUSupply fixture un…
Building supply sizeType L copper, 1.265″ bore1¼″
Simultaneous demandfrom the Hunter curve — the whole point of fixture units31GPM
Supply fixture units80WSFU
Velocity at that flowceiling is 8 ft/s for cold, 5 for hot7.9ft/s
Friction over the run250 ft of 1¼″ at 31 GPM22.3psi
Pressure left at the fixtureassuming 60 psi at the main, an 8 psi meter, and one storey of rise25psi

Notes

  • 80 fixture units is 31 GPM, not 80 GPM, and that gap is the entire reason fixture units exist. Nobody runs every tap at once. The Hunter curve converts a count of fixtures into the flow that actually happens together, and it flattens hard: doubling the fixtures from 25 to 50 raises demand from 16 to 24 GPM, not from 25 to 50.
  • Adding up the fixtures' rated flows instead is how houses end up with pipe two sizes too big. Oversized supply is not harmless: hot water takes longer to arrive because there is more cold water sitting in the line ahead of it, more water is wasted waiting, and the extra volume sits still long enough to matter for water quality.
  • Velocity is the ceiling, and it is about noise and erosion, not about pressure. 1¼″ at 31 GPM runs 7.9 ft/s. Past 8 ft/s a copper line becomes audible and starts eroding the inside of its elbows; hot water is normally held to 5 ft/s because erosion accelerates with temperature.
  • 25 psi at the fixture is marginal. Most fittings want 20 psi to work and 45 to feel good, and this calculation already assumed a healthy 60 psi at the meter. If the street pressure is lower than that, or the run is longer, the answer is a larger supply — or a booster pump if the street itself is the limit.
  • The service line from the street is a separate question, and it is usually the real bottleneck. A 1¼″ building supply behind a ¾″ service from the main is limited by the ¾″. Older houses often have a galvanised service that has narrowed to half its bore with corrosion — no amount of repiping inside the house fixes that.
  • Fixture unit values are not intuitive, so use the code table. A bathtub is 4 WSFU, a lavatory 1, a flush-tank toilet 2.2, a hose bib 2.5, a dishwasher 1.4. A typical three-bathroom house lands somewhere between 30 and 45 WSFU once the kitchen, laundry and outside taps are counted.

80 fixture units is 31 GPM

Not 80 GPM, and that gap is the entire reason fixture units exist. Nobody opens every tap at once. The Hunter curve converts a count of fixtures into the flow that realistically happens together, and it flattens hard as the count grows.

Over a 250 ft developed length that demand calls for 1¼″ pipe, running at 7.9 ft/s and losing 22.3 psi to friction along the way.

Bigger is not safer

Adding up each fixture's rated flow instead of using the curve is how houses end up with supply pipe two sizes too large. Oversized pipe holds more cold water ahead of the hot, so hot water takes longer to arrive and more is wasted waiting for it. The water also sits still longer, which matters for quality.

The service line usually decides everything

1¼″ inside the house behind a ¾″ service from the street is limited by the ¾″. On older properties the service is often galvanised and has corroded to half its original bore — no amount of repiping inside the walls fixes that, and it is the first thing to check when pressure is poor everywhere at once.

Counting fixture units

A bathtub is 4, a lavatory 1, a flush-tank toilet 2.2, a hose bib 2.5, a dishwasher 1.4. A typical three-bathroom house lands between 30 and 45 once the kitchen, laundry and outside taps are counted.