What size vent for a 3″ drain 80 feet away?
| Vent size | 3″ |
|---|---|
| Minimum by the half-rulehalf of a 3″ drain, never below 1¼″ | 1½″ |
| Developed lengthmeasured along the pipe — elbows, offsets and the vertical, not the straight line to the roof | 80ft |
| Length thresholdpast this, go up a size | 40ft |
| DFU a 3″ branch carries | 20DFU |
Notes
- Two rules, and people only remember the first. A vent is never smaller than half the drain it serves and never below 1¼″ — that gives 1½″ here. The second rule is developed length: friction grows with the run, so a long vent has to be larger. At 80 ft that pushes this one to 3″.
- Developed length is measured along the pipe. Every elbow, every offset and the whole vertical rise count. It is not the distance from the fixture to the roof measured on a drawing — running 60 ft of 1½″ because the roof looks close is exactly how a trap at the far end gets siphoned dry.
- What the vent actually does is protect the trap seal. Water falling down a stack drags air with it. Without a path for replacement air, that suction pulls the water out of the nearest trap, and then sewer gas has an open door into the room. A vent that is undersized does not fail loudly — it fails as a smell nobody can place.
- A dry trap smells the same as a broken one. Floor drains and guest bathrooms that go months without use lose their seal to evaporation, not to venting. Before re-plumbing anything, pour a bucket of water down and wait a day.
- Figures here follow the IPC. UPC jurisdictions differ on several points — wet venting and island fixtures especially — and the local inspector decides. Use this to size a plan and to read a quote, not to argue at inspection.
A 3″ drain with 80 ft of vent
3″. The half-rule alone would give 1½″; developed length is what moves it.
Two rules, and people only remember the first
A vent is never smaller than half the drain it serves, and never below 1¼″.
The second rule is developed length. Friction grows with the run, so a long vent has to be larger. Past about 40 ft, go up a size.
Developed length is measured along the pipe
Every elbow, every offset and the whole vertical rise count.
It is not the distance from the fixture to the roof on a drawing. Running 60 ft of 1½″ because the roof looks close is exactly how a trap at the far end gets siphoned dry.
What the vent is actually for
Water falling down a stack drags air with it. Without a path for replacement air, that suction pulls the water out of the nearest trap — and then sewer gas has an open door into the room.
An undersized vent does not fail loudly. It fails as a smell nobody can place.
A dry trap smells the same as a broken one
Floor drains and guest bathrooms that go months unused lose their seal to evaporation, not to venting.
Pour a bucket of water down and wait a day before re-plumbing anything.
Figures follow the IPC. UPC jurisdictions differ on wet venting and island fixtures, and the local inspector decides.
Nearby sizes
- What size vent for a 2″ drain 80 feet away?
- What size vent for a 4″ drain 80 feet away?
- What size vent for a 1.5″ drain 80 feet away?
- What size vent for a 3″ drain 60 feet away?
- What size vent for a 3″ drain 100 feet away?
- What size vent for a 3″ drain 50 feet away?
- What size vent for a 3″ drain 120 feet away?